Owner’s ManualOxygen Therapy DoorConverts standard Regal cage into anoxygen therapy chamberModels to fit most single-door Regal cagesDoor-mounted t
6SSCI - Suburban Surgical Company, Inc.Chapter 1 - General InformationComments:
Form No. 702703 Rev. E August, 2006 7Owner’s Manual - Oxygen Therapy DoorUnpacking andInspectionIf the shipping container appears damaged in a
8 SSCI - Suburban Surgical Company, Inc.Chapter 2 - Installation and Setup1. With a 1/4 in. or smaller punch and a small hammer, removeboth hinge pin
Form No. 702703 Rev. E August, 2006 9Owner’s Manual - Oxygen Therapy Door6. On the nebulizer extension, squeeze the two ends of thecotter pin
10 SSCI - Suburban Surgical Company, Inc.Chapter 2 - Installation and SetupComments:
Form No. 702703 Rev. E August, 200611Owner’s Manual - Oxygen Therapy DoorDoor and LatchDoor SealsThe door has flexible rubber seal strips (Fig
12 SSCI - Suburban Surgical Company, Inc.Chapter 3 - Operating and CleaningIce TrayThe ice tray can be used for ice baths, warm water, warm chemicalpa
Form No. 702703 Rev. E August, 200613Owner’s Manual - Oxygen Therapy DoorMaximum/MinimumTemperature andHumidity RecordingAs the gauge operates
14 SSCI - Suburban Surgical Company, Inc.Chapter 3 - Operating and CleaningUsing the NebulizerWe at SSCI are not licensed veterinarians. Please use yo
Form No. 702703 Rev. E August, 200615Owner’s Manual - Oxygen Therapy DoorOxygenConcentrationControl4. Set the oxygen flow to 10 liters per min
© Copyright 2006 by Suburban Surgical Co., Inc. All rights reserved.No part of this document may be reproduced or utilized in any form or by any means
16 SSCI - Suburban Surgical Company, Inc.Chapter 3 - Operating and CleaningCleaning InstructionsYou will no doubt want to clean your oxygen door and c
Form No. 702703 Rev. E August, 2006 17Owner’s Manual - Oxygen Therapy DoorReplacement PartsTable 2 lists the replacement parts available for th
18 SSCI - Suburban Surgical Company, Inc.Chapter 4 - Repairs and ReplacementsParts OrderingProcedure Many of the threaded fasteners used on SSCI prod
Form No. 702703 Rev. E August, 2006 19Owner’s Manual - Oxygen Therapy DoorProceduresNebulizer Assembly,CompleteThis is the complete nebulizer a
20 SSCI - Suburban Surgical Company, Inc.Chapter 4 - Repairs and ReplacementsNebulizer OxygenSupply HoseP/N 7504925. Attach the free end of the nebuli
Form No. 702703 Rev. E August, 2006 21Owner’s Manual - Oxygen Therapy DoorTools Required 5/8 in. open-end wrench Utility knifeProcedureThe ho
22 SSCI - Suburban Surgical Company, Inc.Chapter 4 - Repairs and ReplacementsThe nebulizer extension is a 2 in. long stainless steel tube thatprovides
Form No. 702703 Rev. E August, 2006 23Owner’s Manual - Oxygen Therapy DoorRemoval - New-style Gauge1. Open the cage door.2. With a Phillips scr
24 SSCI - Suburban Surgical Company, Inc.Chapter 4 - Repairs and Replacements6. Loosen the gauge bracket nuts and remove the gauge fromthe door.7. Wit
Form No. 702703 Rev. E August, 2006 25Owner’s Manual - Oxygen Therapy DoorHang the new ice tray on the button hooks provided on the door(Figure
Form No. 702703 Rev. E August, 2006 iOwner’s Manual - Oxygen Therapy DoorTable of ContentsChapter 1 - General Information ...
26 SSCI - Suburban Surgical Company, Inc.Chapter 4 - Repairs and ReplacementsThe following instructions cover both the seal strip retainers and thesea
Form No. 702703 Rev. E August, 2006 27Owner’s Manual - Oxygen Therapy Door5. If you are replacing the seal strip, hold the new strip inposition
28 SSCI - Suburban Surgical Company, Inc.Chapter 4 - Repairs and ReplacementsTable 4. Seal Strip Part NumbersledoMrooD snoisnemiDrooD N/PpirtSlaeS yt
Form No. 702703 Rev. E August, 200629Owner’s Manual - Oxygen Therapy DoorGeneralThe following procedures will help you fix most of the problem
30 SSCI - Suburban Surgical Company, Inc.Chapter 5 - TroubleshootingReturning theOxygen TherapyDoor for RepairsRMA NumbersIf your door should require
Form No. 702703 Rev. E August, 200631Owner’s Manual - Oxygen Therapy DoorThere is no oxygen flow into the cage.First: Make sure that the oxyg
32 SSCI - Suburban Surgical Company, Inc.Chapter 5 - TroubleshootingThere is excessive oxygen leakage from the cage.Note: Some oxygen leakage is norm
Form No. 702703 Rev. E August, 200633Owner’s Manual - Oxygen Therapy DoorThe door does not close or latch correctly.The latch brackets are pro
34 SSCI - Suburban Surgical Company, Inc.Chapter 5 - TroubleshootingOne or both of the gauges does not read correctly.Remedial ActionOne or both of th
Inside back coverThis page left blank intentionally.
iiSSCI - Suburban Surgical Company, Inc.Table of ContentsCleaning Instructions ...
Form No. 702703 Rev. E 08/06Suburban Surgical Company, Inc.275 Twelfth Street Wheeling, IL 60
Form No. 702703 Rev. E August, 20061Owner’s Manual - Oxygen Therapy DoorIntroductionThe SSCI Oxygen Therapy Door transforms your standard Rega
2SSCI - Suburban Surgical Company, Inc.Chapter 1 - General InformationWARNINGSInformation andSafety NoticesThroughout this manual you will find text u
Form No. 702703 Rev. E August, 20063Owner’s Manual - Oxygen Therapy DoorCare and Cleaning ofStainless SteelIntroductionStainless steel is stee
4SSCI - Suburban Surgical Company, Inc.Chapter 1 - General InformationCleaningRequirementsEffect on WarrantySafetyThe large selection of brands and co
Form No. 702703 Rev. E August, 20065Owner’s Manual - Oxygen Therapy DoorSSCI ContactInformationContact SSCI Customer Service by mail, telephon